Integral Experiments Data, Databases, Benchmarks and Safety Joint Projects
CSNI1008 G2/716.
last modified: 13-DEC-1999 | catalog | new | search |

CSNI1008 G2/716.

G2/716, Westinghouse G2 Loop Test Facility

top ]
1. NAME OR DESIGNATION:  G2/716.
top ]
2. COMPUTERS

To submit a request, click below on the link of the version you wish to order. Rules for end-users are available here.

Program name Package id Status Status date
G2/716 CSNI1008/01 Arrived 13-DEC-1999

Machines used:

Package ID Orig. computer Test computer
CSNI1008/01 Many Computers
top ]
3. DESCRIPTION OF TEST FACILITY:  Westinghouse G2 loop test facility.
top ]
4. DESCRIPTION OF TEST

Heat transfer measurements above two-phase mixture level under core uncovery conditions are carried out in a bundle of 336 heater rods. Heat transfer data obtained above the froth level from the bundle in PWR uncovery tests are evaluated. These data are compared with existing heat transfer correlations for core heat up. An appropriate heat transfer model for use in small-break loss-of-coolant accident analysis can be derived.
top ]
5. RESTRICTIONS ON THE COMPLEXITY OF THE PROBLEM: EXPERIMENTAL LIMITATIONS OR SHORTCOMINGS
top ]
6. PHENOMENA TESTED

- Levels
- Differential pressure
- Pressure
- Power
- Temperature
top ]
7. UNUSUAL FEATURES: SPECIAL FEATURES OF EXPERIMENT
top ]
8. RELATED OR AUXILIARY PROGRAMS: COUNTERPART EXPERIMENTS
top ]
9. STATUS
Package ID Status date Status
CSNI1008/01 13-DEC-1999 Arrived at NEADB
top ]
10. REFERENCES
CSNI1008/01, included references:
- Heat Transfer Above the Two-Phase Mixture Level Under Core Uncovery
Conditions in a 336-Rod Bundle, Vol 1 & 2 EPRI NP-1692, RP1760-1
Interim Report, January 1981
- Heat Transfer Above the Two-Phase Mixture Under Core Uncovery
Conditions in a 336-Rod Bundle, Data Evaluation and Analysis
EPRI NP-2161, RP1760-1, Final Report, December 1981
top ]
11. TEST DESIGNATION:  716
top ]
12. PROGRAMMING LANGUAGE(S) USED
No specified programming language
top ]
15. ESTABLISHMENT

       Electric Power Research Institute
       3412 Hillview Ave
       P.O. Box 10412
       PALO ALTO, CA 94303, USA
top ]
16. MATERIAL AVAILABLE
CSNI1008/01
CCVM data        mag tape                 (TOTAL:  7,930,720 bytes) CVMTP
CCVM data        mag tapeLevels                      128,480        CVMTP
CCVM data        mag tapeDifferential pressure       548,960        CVMTP
CCVM data        mag tapePressure                    175,200        CVMTP
CCVM data        mag tapePower                       128,480        CVMTP
CCVM data        mag tapeTemperature               6,949,600        CVMTP
top ]
17. CATEGORIES
  • Y. Integral Experiments Data, Databases, Benchmarks

Keywords: heat transfer, loss-of-coolant accident, reactor cores, two-phase flow.